Tryag File Manager
Home
-
Turbo Force
Current Path :
/
proc
/
self
/
root
/
usr
/
share
/
doc
/
mgetty-1.1.33
/
Upload File :
New :
File
Dir
//proc/self/root/usr/share/doc/mgetty-1.1.33/modems.db
WARNING: most information in this file is for older versions of policy.h, some of the definition names have changed, others are used slightly different. Make sure that you have read *ALL* of the comments in there, and understand them! gert ---------------------------------------------------- Modem brand/model: "Dynalink 9624AP" at+fmfr? EXAR at+fmdl? 9648,2,E,290X at+frev? 10, 10, 92 REVISION X 2.0 ati3 ADN-06 ati4 MARROW 2900KSX V2.0B 11-05-1992 tested on: linux 0.99p10 working: sendfax, mgetty(?) remarks: avoid this cheap and nasty modem if you possibly can. It needs: delay(500) at the end of fax_open_device(), sendfax.c line 111 delay(500) after the call to fax_send_page(), sendfax.c line 533 "\d\d\d" in all the AT-commands in init_chat_seq, mgetty.c contributor: a.j.scholl@durham.ac.uk #define DATA_FLOW FLOW_HARD #define FAXREC_FLOW FLOW_HARD | FLOW_SOFT #define FAXSEND_FLOW FLOW_HARD #define FAX_SEND_BAUD 19200 #define FAX_MODEM_HANDSHAKE "" #define FAX_SET_CSTOPB 1 /* for when you've added this option :-) */ ---------------------------------------------------- Modem brand/model: "Zoltrix Platinum Series 14.4" at+fmfr? ROCKWELL at+fmdl? RC32ACL at+frev? V1.410-AP39 ati3 ati6 RCV144DP; Rev CA tested on: linux 0.99p7 working: mgetty, sendfax remarks: great modem! In my uucp network of 16 machines, this modem averages at 1700 bps, while other brand name modems such as the Trailblazer PEP maxes out at about 1570. contributor: whome!light-house!las@planix.com #define DATA_FLOW FLOW_HARD #define FAX_COMMAND_DELAY 50 #define FAXREC_FLOW FLOW_SOFT #define FAXSEND_FLOW FLOW_SOFT #define FAX_SEND_BAUD 38400 #define FAX_MODEM_HANDSHAKE "AT&K3" #define MODEM_INIT_STRING "ATS0=0V1Q0&D3&K3%C1W1" ---------------------------------------------------- Modem brand/model: PCMCIA Modem HOTLINE 960 CC HL9672CC AT+FMFR? HOTLINE AT+FMDL? Handy 9672 CC AT+FREV? Version 1.03H ATI3 V1.03DP ATI4 Handy 9672 CC H1_103 AT+FDCC=? (0,1),(0-3),(0-2),(0-2),(0,1),0,0,(0-7) tested on: OS: Linux, Kernel: 1.0, Distribution: Slackware 1.2.0 Computer: Toshiba T4700C Notebook working: sendfax, mgetty contributor: lauther@zfe.siemens.de remarks: can only do 9600 bps #define DEFAULT_PORTSPEED 19200 #define MODEM_INIT_STRING "ATS0=0Q0&D3&K3" #define MODEM_CMD_SUFFIX "\r" #define DO_CHAT_SEND_DELAY 50 #define FAX_COMMAND_DELAY 50 #define DATA_FLOW FLOW_HARD #define FAXREC_FLOW FLOW_HARD | FLOW_SOFT #define FAXSEND_FLOW FLOW_HARD | FLOW_SOFT #define FAX_SEND_BAUD 19200 #define FAX_MODEM_HANDSHAKE "AT&K3" ---------------------------------------------------- Modem brand/model: Creatix (1&1) Polimedia 14400 voice / fax modem AT+FMFR? Creatix AT+FMDL? LC144VF AT+FREV? V1.41 ATI0 14400 ATI1 007 ATI3 V1.400/T4-DS29F ATI4 Creatix Polymedia GmbH V1.41 29/11/93 ATI6 RCV144DPi Rev CA AT+FDCC=? (0,1),(0-5),(0-2),(0-2),(0,1),0,0,(0-7) tested on: ??? working: sendfax, mgetty contributor: andreas@malcolm.in-chemnitz.de #define DEFAULT_PORTSPEED 38400 #define MODEM_INIT_STRING "ATS0=0Q0&D3&K6" #define MODEM_CMD_SUFFIX "\r" #define DO_CHAT_SEND_DELAY 50 #define FAX_COMMAND_DELAY 50 #define DATA_FLOW FLOW_HARD #define FAXREC_FLOW FLOW_HARD | FLOW_SOFT #define FAXSEND_FLOW FLOW_HARD | FLOW_SOFT #define FAX_RECV_SWITCHBD 19200 #define FAX_SEND_BAUD 19200 #define FAX_MODEM_HANDSHAKE "AT&K6" Remark: &K6 is not a good idea on systems supporting RTS/CTS flow control. Better use &K3 instead. (gert). ---------------------------------------------------- Modem brand/model: Creatix (1&1) Polymedia 14400 voice / fax modem AT+FMFR? ROCKWELL AT+FMDL? RC32ACL AT+FREV? V1.600-DS29F ATI0 14400 ATI1 007 ATI3 V1.600-DS29F ATI4 Creatix Polymedia GmbH germ V1.61 14/12/94 ATI6 RCV144DPi Rev CA AT+FDCC=? (0,1),(0-5),(0-2),(0-2),(0,1),0,0,(0-7) tested on: Linux 1.2.8, 486/33, 16550A working: sendfax, mgetty, vgetty (see below), 0.99-Sep23 contributor: jens@physiology.rwth-aachen.de #define DEFAULT_PORTSPEED 38400 #define MODEM_INIT_STRING "AT&F0S0=0Q0&D3&K6" #define MODEM_CMD_SUFFIX "\r" #define DO_CHAT_SEND_DELAY 50 #define FAX_COMMAND_DELAY 50 #define DATA_FLOW FLOW_HARD #define FAXREC_FLOW FLOW_HARD | FLOW_SOFT #define FAXSEND_FLOW FLOW_HARD | FLOW_SOFT #define FAX_RECV_SWITCHBD 19200 #define FAX_SEND_BAUD 38400 #define FAX_MODEM_HANDSHAKE - nothing special given - Remark: &K6 means RTS/CTS *and* XON/XOFF for that modem. This version (1.6) doesn't support ADPCM-3 ! AT#VBS=3 -> Error. In principle the modem works with vgetty, BUT the modem does not give any DLE-shielded code when recording from the telefone line. As long as you do fax sending or login-attempts during the greetin message, everything is fine. But during recording neither silence nor busy nor data/fax are recognized. So vgetty records as long as the maximum time given for recording. (jens). ---------------------------------------------------- Modem brand/model: "Practical Peripherals PM14400FXMT" at+fmfr? 2.30 (c) Practical Peripherals Inc. 1993. at+fmdl? PM14400FXMT [6R3] 2.30 at+frev? Version 2.30 ati3 PM14400FXMT [6R3] Version 2.30 (c) Practical Peripherals Inc. 1993.PM14400FXMT [6R3] Version 2.30 (c) Practical Peripherals Inc. 1993. ati4 a097840F284C6703F bC60004000 r1001111171012000 r3000111010000000 tested on: HP-UX 9.01 working: mgetty (both fax and dialin) remarks: Once I got all the settings correct it has worked very well. It seems to have very good response even on 'dirty' lines. contributor: noorder@tac3.vv.hac.com #define DATA_FLOW FLOW_HARD #define FAXREC_FLOW FLOW_HARD | FLOW_SOFT #define FAXSEND_FLOW FLOW_HARD | FLOW_SOFT #define FAX_SEND_BAUD 38400 #define FAX_MODEM_HANDSHAKE "AT&R0" #define MODEM_INIT_STRING "ATS0=0&Q9&D3&K4" #define DEFAULT_PORTSPEED 38400 #define MODEM_CMD_SUFFIX "\r" #define DO_CHAT_SEND_DELAY 50 #define FAX_COMMAND_DELAY 50 #define FAX_RECV_SWITCHBD 19200 ----------------------------------------------------------------------- Modem brand/model: Practical Peripherals PM14400FXMT at+fmfr? 2.42 (c) Practical Peripherals Inc. 1993. at+fmdl? PM14400FMXT [6R4] 2.42 at+frev? Version 2.42 ati3 PM14400FMXT [6R4] Version 2.42 (c) Practical Peripherals Inc. 1993. ati4 a097840F284C6703F bC60004000 r1001111171012000 r3000111010000000 tested on: Linux 1.0 (Slackware 1.2.0) working: sendfax, mgetty remarks: Good modem; can handle ALL incoming data calls at all speeds, plus *MOST* incoming FAXes (some paper machines give +FHNG:100 @ 2400 baud). Good manual, but (like others, no +F commands listed. My guess is about 75% Class 2 commands implemented. contributor: paul@edgewood.portland.or.us #define DEFAULT_PORTSPEED 38400 /* 57600 w/ 'setserial spd_hi' */ #define FAX_RECV_SWITCHBD 19200 #define FAX_SEND_BAUD 19200 #define DATA_FLOW FLOW_HARD #define FAXREC_FLOW FLOW_HARD | FLOW_SOFT #define FAXSEND_FLOW FLOW_HARD | FLOW_SOFT #define FAX_MODEM_HANDSHAKE "" #define MODEM_INIT_STRING "\\dATM0S0=0Q0&C1&D2&K3&Q5" --------------------------------------------------- Modem brand/model: "ZyXEL 1496 E+" at+fmfr? ZyXEL at+fmdl? U1496E V 6.12 P at+frev? U1496E V 6.12 P ati 1496 tested on: DEC OSF/1 v1.2-hybrid SCO Unix ODT 3.0 Linux (various) working: sendfax, mgetty, vgetty contributor: Marc@Synergytics.Com #define DATA_FLOW FLOW_HARD #define FAXREC_FLOW FLOW_HARD | FLOW_SOFT #define FAXSEND_FLOW FLOW_HARD | FLOW_SOFT #define FAX_SEND_BAUD 38400 #define FAX_MODEM_HANDSHAKE "AT&H3" #define MODEM_INIT_STRING "ATS0=0Q0&D3&H3&N0&K4" --------------------------------------------------- Modem brand/model: ZyXEL U1496EG+ AT+FMFR? ZyXEL AT+FMDL? U1496EG V 6.12 P AT+FREV? U1496EG V 6.12 P ATI3 (OK) ATI4 (OK) AT+FDCC=? (0,1),(0-5),(0-2),(0-2),(0-1),(0),(0),(0-7) tested on: AIX 3.2.5 working: sendfax, mgetty (both 0.20) contributor: hm@ix.de remarks: #define DEFAULT_PORTSPEED 38400 #define MODEM_INIT_STRING "ATL0S0=0Q0&D3&H3&N0&K4" #define MODEM_CMD_SUFFIX "\r" #define DO_CHAT_SEND_DELAY 50 #define FAX_COMMAND_DELAY 50 #define DATA_FLOW FLOW_HARD #define FAXREC_FLOW FLOW_HARD | FLOW_SOFT #define FAXSEND_FLOW FLOW_SOFT #define FAX_SEND_BAUD 38400 #define FAX_MODEM_HANDSHAKE "AT&K3" --------------------------------------------------- Modem brand/model: GVC GM-144VBIS+ AT+FMFR? EXAR AT+FMDL? 9648,2,E,290X AT+FREV? GM-144VBIS+; RC9696/14 ATI3 170 ATI4 GM-144VBIS+; RC9696/14 AT+FDCC=? (0-1),(0-3),(0-3),(0-2),(0-2),(0),(0),(0-7) tested on: AIX 3.2.5 working: mgetty-0.20 contributor: hm@ix.de remarks: (sendfax is not tested and not intended to) #define DEFAULT_PORTSPEED 38400 #define MODEM_INIT_STRING "ATL0S0=0Q0&D3\\\\Q3&S0%C\\\\N6" #define MODEM_CMD_SUFFIX "\r" #define DO_CHAT_SEND_DELAY 50 #define FAX_COMMAND_DELAY 50 #define DATA_FLOW FLOW_HARD #define FAXREC_FLOW FLOW_HARD | FLOW_SOFT #define FAXSEND_FLOW FLOW_SOFT #define FAX_SEND_BAUD 38400 #define FAX_MODEM_HANDSHAKE "AT\\\\Q3&S0" ---------------------------------------------------- Modem brand/model: "Aceex 1496" at+fmfr? EXAR at+fmdl? 9624,2,E,290E at+frev? Sep-24-1991 ati3 ati6 V.110 APR-30-1993 (ROCKWELL CHIP SET) DM1414/2A/RC144DP-21/PCB:490-09636-xx BZT POSTZULASSUNG-FIRMWARE VERSION:V.105 tested on: SVR4.2 (UnixWare 1.1.1) working: mgetty, sendfax remarks: fax send / receive with max. 19200 bd This german telekom approved modem doesn't allow ATA without an incoming call (real RING). So kill -USR1 <mgetty-pid> doesn't work. contributor: 100272.3376@compuserve.com (Achim Buerger) #define DATA_FLOW FLOW_HARD #define FAX_COMMAND_DELAY 50 #define FAXREC_FLOW FLOW_HARD | FLOW_SOFT #define FAXSEND_FLOW FLOW_HARD | FLOW_SOFT #define DEFAULT_PORTSPEED 19200 #define FAX_SEND_BAUD 19200 #define FAX_MODEM_HANDSHAKE "AT\\Q3&S0" #define MODEM_INIT_STRING "ATS0=0Q0&D3\\\\Q3%C1&N0&K3" ---------------------------------------------------- Modem brand/model: "Dago Speed" from Speedy Technology, Koenigstein at+fmfr? ROCKWELL at+fmdl? RC32AC-W at+frev? V1.15 ati3 V1.15 ati4 RC144DP tested on: linux 0.99p15, 486DX50, UART 16550A mgetty version: 0.21 working: sendfax, mgetty remarks: sendfax: works perfectly (about 50 multi-page faxes sent without problems) mgetty: my Dago does not always recognize fax calls correctly, especially from some fax machines, but fax calls from a Creatix modem are *almost* always recognized correctly. When a fax call is recognized correctly, mgetty has no problems. Defining FAX_RECV_SWITCHBD 19200 is necessary with my modem version. Data calls are always recognized correctly (tested with Creatix and Zyxel). contributor: schaefer@dfki.uni-sb.de (Ulrich Schaefer) #define DEFAULT_PORTSPEED 38400 #define DATA_FLOW FLOW_HARD #define FAXREC_FLOW FLOW_HARD #define FAXSEND_FLOW FLOW_HARD #define DO_CHAT_SEND_DELAY 100 #define FAX_COMMAND_DELAY 100 #define FAX_RECV_SWITCHBD 19200 #define FAX_SEND_BAUD 38400 #define FAX_MODEM_HANDSHAKE "AT&K3" #define MODEM_INIT_STRING "ATS0=0V1Q0&D3&K3" mgetty.c: int toggle_dtr_waittime = 2000; /* otherwise reset may fail */ ----------------------------------------------------------------------- Modem: SupraFax v.32bis System Decstation 5000/200 OS: Ultrix V4.2 (Rev. 96) #define DEFAULT_PORTSPEED 38400 #define MODEM_INIT_STRING "AT&F2M0L0S0=0V1Q0&D3&K3%C1W1" #define DEFAULT_MODEMTYPE "auto" #define DO_CHAT_SEND_DELAY 50 #define FAX_COMMAND_DELAY 50 #define DATA_FLOW FLOW_HARD #define FAXREC_FLOW FLOW_SOFT #define FAXSEND_FLOW FLOW_SOFT #define FAX_RECV_SWITCHBD 19200 #define FAX_SEND_BAUD 19200 #define FAX_MODEM_HANDSHAKE "AT&K4" at+fmfr? ROCKWELL at+fmdl? V.32AC at+frev? V1.71-02 TR14-Jxxx-001 ati3 V1.71-02 TR14-Jxxx-001 225 ati5 (c) 1992,93 Supra Corporation Remark: see also Chris Junge's entry below ----------------------------------------------------------------------- Modem brand/model: Holmes Fax'em 96/24 AT+FMFR? EXAR AT+FMDL? 9648,2,E,290X AT+FREV? 9/30/91 9.10 E + V.23 REVISION 2.1D3 ATI3 9/30/91 9.10 E + V.23 REVISION 2.1D3 ATI4 9/30/91 9.10 E + V.23 REVISION 2.1D3 AT+FDCC=? (0,1),(0-3),(0-3),(0-2),(0-2),(0),(0),(0-7) tested on: OS: Linux, Kernel: 0.99pl13, Distribution: Slackware 1.1.2 Computer: Compaq LTE Lite/25c Notebook remarks: introduce additional delays as mentioned in the mgetty-documentation working: sendfax, mgetty contributor: lauther@zfe.siemens.de #define DEFAULT_PORTSPEED 19200 #define MODEM_INIT_STRING "ATS0=0Q0&D3&H3&N0&K4" #define MODEM_CMD_SUFFIX "\r" #define DO_CHAT_SEND_DELAY 50 #define FAX_COMMAND_DELAY 50 #define DATA_FLOW FLOW_HARD #define FAXREC_FLOW FLOW_HARD | FLOW_SOFT #define FAXSEND_FLOW FLOW_HARD | FLOW_SOFT #define FAX_SEND_BAUD 19200 #define FAX_MODEM_HANDSHAKE "" ----------------------------------------------------------------------- Modem brand/model: "ESCOM High speed modem 14400" at+fmfr? EXAR at+fmdl? ROCKWELL 144DP at+frev? E.C. Version 7.1 Date code 921118 ati3 E.C. Version 7.1 Date code 921118 ati6 FM-144DHVBIS+/R1 V3.1o tested on: linux 1.1.20 working: sendfax, (mgetty?) remarks: sendfax works only after padding blank lines with zeros, e.g. by means of ..| g3cat -p 20 | .. If this is not done, the machine at the other end may hang up irrecoverably. contributor: nuk111@cvx12.inet.dkfz-heidelberg.de #define DATA_FLOW FLOW_HARD #define FAX_COMMAND_DELAY 50 #define FAXREC_FLOW FLOW_SOFT #define FAXSEND_FLOW FLOW_SOFT #define FAX_SEND_BAUD 19200 (38400 seems to be o.k., too) #define FAX_MODEM_HANDSHAKE "AT\\Q3\\N6" #define MODEM_INIT_STRING "ATS0=0Q0&D3\\Q3\\N6" ----------------------------------------------------------------------- Modem brand/model: ESCOM Data Hawk 14400 at+fmfr? EXAR at+fmdl? ROCKWELL 144DP at+frev? E.C. Version : 7.1 Date code 921118 CURRENT COUNTRY : 5 GERMANY ati1 122 FM-144DHVBIS+/R1 V3.1o ati3 CURRENT COUNTRY : 5 GERMANY ati6 FM-144DHVBIS+/R1 V3.1o MODEM CHIP : ROCKWELL RC144DP H-CODE FAX CLASS 2 contributor: stg@gandalf.han.de ----------------------------------------------------------------------- Modem brand/model: "Boca V.32bis" at+fmfr? ROCKWELL at+fmdl? RC32ACL at+frev? V1.005 ati3 V1.005 ati4 Boca Research, M144GRA tested on: SINIX-L 5.40 A20N5 MX300I i386 working: sendfax, mgetty/fax receive remarks: Not really tested, it simply works stable enough for me. The special condition is that the MX300 on which mgetty runs has no hardware handshake. contributor: fte@gecko.de (Frank Tegtmeyer) #define DEFAULT_PORTSPEED 19200 #define MODEM_INIT_STRING "ATS0=0Q0" all other defined in modem setup #define DATA_FLOW FLOW_SOFT #define FAXREC_FLOW FLOW_SOFT #define FAXSEND_FLOW FLOW_SOFT #define FAX_SEND_BAUD 19200 #define FAX_MODEM_HANDSHAKE "" ----------------------------------------------------------------------- Modem brand/model: Supra FAX Modem V.32bis at+fmfr? ROCKWELL at+fmdl? V.32AC at+frev? V1.80-06v TR14-Jxxx-001 ati3 V1.80-06v TR14-Jxxx-001 216 ati4 a007050C08484402F / bC60000000 / r16E5111151012000 / r3000111170000000 tested on: Linux version 1.1.44 working: sendfax, mgetty contributor: chris@cj.in-berlin.de remarks: If ATi3 reveals v1.7x and/or you are having faxing problems, especially with drop-outs between pages. A fix is don't define &D3 in the MODEM_INIT_STRING. Use &D2 and define in mg_m_init.c: "\\d\\d\\d+++\\d\\d\\d\r\\dATZQ0V1", "OK" There is another bug with AT+FCLASS=0: it sets &K3 to &K0 Here is a little patch: *** mg_m_init.c.orig Sun Aug 14 13:32:48 1994 --- mg_m_init.c Sun Aug 14 10:51:27 1994 *************** *** 135,140 **** --- 135,145 ---- { lprintf( L_MESG, "huh? Cannot set +FDCC parameters" ); } + + if ( mdm_command( "AT &K3", fd ) == FAIL ) + { + lprintf( L_MESG, "cannot set &K3 handshake" ); + } return SUCCESS; } #define DEFAULT_MODEMTYPE "auto" #define DATA_FLOW FLOW_HARD #define FAX_COMMAND_DELAY 50 #define FAXREC_FLOW FLOW_HARD #define FAXSEND_FLOW FLOW_HARD #define FAX_SEND_BAUD 19200 #define FAX_RECV_SWITCHBD 19200 #define MODEM_INIT_STRING "ATS0=0Q0&D3" #define FAX_MODEM_HANDSHAKE "AT&K3" ----------------------------------------------------------------------- Modem brand/model: "Telebit T2500" ati4 a037800C004420 b100000000 tested on: linux 1.1p62, 486DX50, UART 16450A mgetty version: 0.21 working: mgetty remarks: No fax option available with this modem :-c contributor: frank@gzunda.mayn.sub.de (Stefan Frank (sf)) #define DEFAULT_PORTSPEED 19200 #define DATA_FLOW FLOW_HARD #define DO_CHAT_SEND_DELAY 500 #define FAX_COMMAND_DELAY 500 #define MODEM_INIT_STRING "ATS0=0V1Q0&D3&K3" mgetty.c: int toggle_dtr_waittime = 2000; /* otherwise reset may fail */ ----------------------------------------------------------------------- Modem brand/model: U.S. Robotics Courier V.34 Fax ati0 2886 ati7 Configuration Profile... Product type US/Canada External Options V32bis,Terbo,V.FC,V.34 Fax Options Class 1/Class 2.0 Clock Freq 20.16Mhz Eprom 256k Ram 32k Supervisor date 12/02/94 DSP date 12/02/94 Supervisor rev 6.0.5 DSP rev 1.0.6 tested on: linux 1.0.9 working: sendfax, mgetty-0.22 remarks: This "V.Everything" modem connects with V.34, V.FC, and V.32terbo in addition to the standard lower speeds (but not HST). It has adaptive speed leveling to dynamically adjust to line conditions. It supports fax classes 1 and 2.0. I use the linux spd_vhi serial port setting together with 38400 to lock the modem at 115200 baud. Note that it does not require the "#define FAX_USRobotics" in policy.h. I use the default modem switches and all the default settings obtained by AT&F1 with one exception: I set ATT so that "ATD" will use tones to dial instead of pulses, by default. When sending to some older fax machines (Amstrad, Pitney-Bowes, Sharp) fails, try setting S36=14 for longer timeouts. Thanks to sbromwic@usr.com for this hint. contributor: hemphill@alumni.caltech.edu contributor2: cb@medat.de (Christoph Brinck) #define DEFAULT_PORTSPEED 38400 #define DATA_FLOW FLOW_HARD #define FAXREC_FLOW FLOW_HARD #define FAXSEND_FLOW FLOW_HARD #define FAX_SEND_BAUD 38400 #define FAX_MODEM_HANDSHAKE "AT&H1" #define MODEM_INIT_STRING "AT&F1&S4T" ----------------------------------------------------------------------- Modem brand/model: Intel High-Speed (14400) Internal Faxmodem AT+FMFR? EXAR AT+FMDL? ROCKWELL 144DP AT+FREV? INTEL 14400I V1.7 MODEM CHIP : ROCKWELL RC144DP FAX CLASS 2 ATI1 046 INTEL 14400I V1.7 ATI3 E.C. Version : 1.6 Date code 930511 ATI4 INTEL 14400I V1.7 MODEM CHIP : ROCKWELL RC144DP FAX CLASS 2 ATI5 as ATI4 ATI6 as ATI4 AT+FDCC=? (0-1),(0-5),(0-3),(0-2),(0-2),(0),(0),(0-7) tested on: Linux 1.1.76, mgetty-sendfax v0.22 working: sendfax, mgetty contributor: jeffrey@thompson.itm.org remarks: Make sure and use &D2 and not &D3. &D3 is reset to &D0! #define DEFAULT_PORTSPEED 19200 #define MODEM_INIT_STRING "ATS0=0Q0&D2\\\\Q3\\\\N3\"H3" #define MODEM_CMD_SUFFIX "\r" #define DEFAULT_MODEMTYPE "auto" #define DO_CHAT_SEND_DELAY 50 #define FAX_COMMAND_DELAY 50 #define DATA_FLOW FLOW_HARD #define FAXREC_FLOW FLOW_HARD | FLOW_SOFT #define FAXSEND_FLOW FLOW_HARD | FLOW_SOFT #define FAX_SEND_BAUD 38400 #define FAX_MODEM_HANDSHAKE "AT\\Q3&S0" #define FAX_MODEM_TTYS "ttyS2" (not cua2) And an AT&V of my modem settings: ACTIVE PROFILE: B1 E1 L2 M0 Q0 T V1 X4 Y0 &C1 &D2 &G0 &P0 &S0 &Y0 \A3 %A013 \C0 %C1 %E1 \G0 \J0 \K5 \N3 \Q3 \T000 \V2 \X0 -J1 "H3 S00:000 S01:000 S02:043 S03:013 S04:010 S05:008 S06:002 S07:120 S08:002 S09:006 S10:014 S11:070 S12:050 S18:255 S23:17H S25:005 S26:001 ----------------------------------------------------------------------- Modem brand/model: Creatix LC 288 FC at+fmfr? ROCKWELL at+fmdl? AC/VFC at+frev? V1.000-DS39 VFC ati0 28800 ati3 V1.000-DS39 VFC ati4 Creatix Polymedia GmbH V1.00 18/08/94 ati6 RC288DPi Rev 05BA at+fdcc=? (0,1),(0-5),(0-2),(0-2),(0,1),0,0,(0-7) tested on: linux 1.1.54, 486DX50, UART 16550A mgetty version: 0.21, 0.23 working: sendfax, mgetty remarks: sendfax and mgetty (fax & logins) work, serving documents for polling with mgetty works, but polling with sendfax does not work (yet) great modem! contributor: schaefer@dfki.uni-sb.de (Ulrich Schaefer) #define DEFAULT_PORTSPEED 38400 (115200 effectively) #define DATA_FLOW FLOW_HARD #define FAXREC_FLOW FLOW_HARD #define FAXSEND_FLOW FLOW_HARD #define DO_CHAT_SEND_DELAY 50 #define FAX_COMMAND_DELAY 50 #define FAX_RECEIVE_SWITCHBD 19200 #define FAX_SEND_BAUD 38400 (115200 effectively) #define FAX_MODEM_HANDSHAKE "&K3" #define MODEM_INIT_STRING "ATS0=0V1Q0&D3&K3&C1" alternatively, leave everything as it is by default, and use switchbd 19200 speed 38400 init-chat "" \d\d\d+++\d\d\dATQ0E1V1H0 OK ATS0=0&D3&C1&K3 OK in mgetty.config. ----------------------------------------------------------------------- Modem brand/model: "TKR Terbo Line" at+fmfr? FAX TEST CODE at+fmdl? AT&T at+frev? FAX Version 3.99 ati3 TKR Terbo Line 19K2/010-Q ati4 007040C004000 tested on: Linux version 1.2.1, mgetty 0.23 working: sendfax, mgetty/fax receive, dialout remarks: The Firmware version 010 (ati3) is the first that is able to decide wether a call is from a modem or fax. Earlier versions receive only in fax mode. You can get the newest version from the TKR bbs (+49 431 336199) or by snail-mail (Phone: +49 431 34589). contributor: fte@impulse.ris.de (Frank Tegtmeyer) #define DEFAULT_PORTSPEED 19200 /* #define USE_GETTYDEFS */ #define MODEM_INIT_STRING "ATX3S0=0Q0&D2&C1&K3" #define MODEM_CMD_SUFFIX "\r\n" #define DEFAULT_MODEMTYPE "cls2" #define DO_CHAT_SEND_DELAY 50 #define FAX_COMMAND_DELAY 50 #define DATA_FLOW FLOW_HARD #define FAXREC_FLOW FLOW_HARD | FLOW_SOFT #define FAXSEND_FLOW FLOW_HARD | FLOW_SOFT /* #define FAX_RECV_SWITCHBD 19200 */ #define FAX_SEND_BAUD 19200 /* #define FAX_SEND_SWITCHBD 19200 */ /* #define FAX_MODEM_HANDSHAKE "AT&H3" */ /* #define FAXSEND_NO_XON */ ----------------------------------------------------------------------- Modem brand/model: XLink V.34 + V.FC AT+FMFR? GVC AT+FMDL? ROCKWELL 144DPI AT+FREV? KA1131-00 ATI0 288 ATI3 E.C. Version : T ATI4 F-1128V/R6 (GM) V6.18.4 MODEM CHIP : ROCKWELL RC288DPi FAX CLASS 1 AND CLASS 2 AT+FDCC=? (0,1),(0-5),(0-3),(0-2),(0),(0),(0),(0-7) tested on: linux 1.2.6, 486DX40, UART16550A mgetty version: 0.23 (Dec 23, 1994) working: mgetty, sendfax remarks: sendfax and mgetty (fax & logins) work, polling with sendfax does not work (yet) contributor: tom@umibox.hanse.de (Thomas Milde, DL1HBT) #define DEFAULT_PORTSPEED 38400 #define DATA_FLOW FLOW_HARD #define FAXREC_FLOW FLOW_HARD #define FAXSEND_FLOW FLOW_HARD #define DO_CHAT_SEND_DELAY 50 #define FAX_COMMAND_DELAY 50 #define FAX_RECEIVE_SWITCHBD 19200 #define FAX_SEND_BAUD 38400 #define FAX_MODEM_HANDSHAKE "&K3" #define MODEM_INIT_STRING "ATS0=0V1Q0&D3&K3&C1" ----------------------------------------------------------------------- Modem brand/model: CPV Stollmann Delta V.34 at+fmfr? GVC at+fmdl? ROCKWELL 144DPI at+frev? KA1131-00 ati0 288 ati3 E.C. Version : T ati4 F-1128V/R6 (GM) V6.18.3 MODEM CHIP : ROCKWELL RC288DPi FAX CLASS 1 AND CLASS 2 at+fdcc=? (0,1),(0-5),(0-3),(0-2),(0),(0),(0),(0-7) tested on: linux 1.1.54, 486DX50, UART 16550A mgetty version: 0.23 of April 10, 1995 working: mgetty and sendfax, no polling available contributor: schaefer@dfki.uni-sb.de (Ulrich Schaefer) policy.h: everything default mgetty.config: speed 115200 switchbd 19200 init-chat ATS0=0V1Q0&D3&C1&K3 OK ----------------------------------------------------------------------- Subject: new entry mgetty+sendfax modem.db From: Thomas Kuerten <kuerten@informatik.tu-muenchen.de> To: gert@greenie.muc.de (Gert Doering) Modem brand/model: USRobotics Sportster V.34 28.800 Fax Modem AT+FMFR? ??? AT+FMDL? ??? AT+FREV? ??? ATI0 2886 ATI1 05B1 ATI4 USRobotics Sportster 28800 Fax Settings... B0 E1 F1 M1 Q0 V1 X4 BAUD=115200 PARITY=N WORDLEN=8 [..] ATI7 Configuration Profile... Product type Germany External Options V32bis,V.FC,V.34 Fax Options Class 1/Class 2.0 tested on: Linux 1.0 (Slackware 1.2.0) Kernel 1.1.59 and 1.2.0 tested on: Solaris 2.5 SunOS 4.1.3 and 4.1.4 working: sendfax, mgetty remarks: "#define FAX_USRobotics" is NOT intended to use with this modem, instead all works fine without, and problems occur IF this is defined. Best modem I ever had, all works fine for sendfax and receivefax, different faxes received, multipage (up to 10) from different countries (Scotland, Italy). mgetty remote login not yet tested. Modem has great connects with V.34 28.800 in data mode, giving rates of 4500 cps for uncompressed and 3400 for compressed data. But only good for stable telefon lines, not very good at scratchy or analog connections. If you have caller ID on your phone line, add AT#CID=1 to your init chat sequence, and mgetty will be able to write the Caller ID to the log files. WARNING: many USR Sportster models are completely unable to send and/or receive faxes. So, if faxing is important for you, DO NOT GET AN USR SPORTSTER. (Get an USR Courier, works very good). contributor: kuerten@informatik.tu-muenchen.de contributor: rrb@cqs.ch /* changed values in policy.h: */ #define MODEM_INIT_STRING "ATZ" #define FAX_MODEM_HANDSHAKE "AT&H3&I2&R2S7=90" /* unchanged: */ #define DEFAULT_PORTSPEED 38400 /* 115200 w/ 'setserial spd_vhi' */ #define DATA_FLOW FLOW_HARD #define FAXREC_FLOW FLOW_HARD | FLOW_SOFT #define FAXSEND_FLOW FLOW_HARD | FLOW_SOFT #define FAX_SEND_BAUD 38400 #define DEFAULT_MODEMTYPE "auto" --------------------------------- schnibbel --------------------------------- Modem: SupraFaxModem 288 V34 tested on: OS: Linux 1.3.28 Computer: 486dx2/66 PCI system with 16450 working: mgetty, sendfax, Version 0.98 contributor: hohndel@aib.com (Dirk H. Hohndel) at+fmfr? Supra Corporation at+fmdl? SupraFAXModem 288 at+frev? V1.200-02-V34_DS ati7 RC288DPi Rev 04BC #define DEFAULT_PORTSPEED 38400 #define MODEM_INIT_STRING "ATS0=0Q0&D3&C1&K3" #define DATA_FLOW FLOW_HARD #define FAXREC_FLOW FLOW_HARD | FLOW_SOFT #define FAXSEND_FLOW FLOW_HARD | FLOW_SOFT #define FAX_RECV_SWITCHBD 19200 all other values left at "default". --------------------------------- schnibbel --------------------------------- Modem: Dynalink 1414VE contributor: sakari@picea.hut.fi #define MODEM_INIT_STRING "ATS0=0N1Q0&D3&K3&Q5" /*#define FAX_MODEM_HANDSHAKE "AT&H3"*/ all other values left at "default" ----------------------------------------------------------------------- Modem brand/model: U.S. Robotics Courier High Speed Modem Dual Standard V.34 Fax with V.Fast Class and V.32bis ati0 3366 ati7 Configuration Profile... Product type Germany External MSK Options HST,V32bis,Terbo,V.FC,V.34 Fax Options Class 1/Class 2.0 Clock Freq 20.16Mhz Eprom 256k Ram 32k Supervisor date 11/07/95 DSP date 07/05/95 Supervisor rev 049-6.2.2 DSP rev 1.2.2 tested on: linux 1.2.13 working: sendfax, mgetty-0.99 from Feb 25, 1996 remarks: it is very important to specify S9=3, default value does not work contributor: vnm@rzbt.fh-hamburg.de policy.h: #define DEFAULT_PORTSPEED 115200 #define MODEM_INIT_STRING "AT&F&A3&B1&H1&R2&D2&C1X7S0=0S9=3S7=90" #define MODEM_CMD_SUFFIX "\r" #define DEFAULT_MODEMTYPE "auto" #define DO_CHAT_SEND_DELAY 50 #define FAX_COMMAND_DELAY 50 #define DATA_FLOW FLOW_HARD #define FAXREC_FLOW FLOW_HARD #define FAXSEND_FLOW FLOW_HARD #define FAX_SEND_BAUD 38400 #define FAX_MODEM_HANDSHAKE "AT&H1" DIP switches: 1 OFF 2 OFF 3 ON 4 OFF 5 OFF 6 OFF 7 OFF 8 ON 9 ON 10 OFF ----------------------------------------------------------------------- Modem brand/model: "Blatzheim GM-288Vc+ FAX" at+fmfr? GVC at+fmdl? ROCKWELL 144DPI at+frev? KA1131-00 ati3 E.C. Version : R ati4 GM-288Vc+ FAX V6.23 Blatzheim GmbH, Bonn MODEM CHIP : ROCKWELL RC288DP/VFC FAX CLASS 1 AND CLASS 2 AT+FDCC=? (0,1),(0-5),(0-3),(0-2),(0,1),(0),(0),(0-7) tested on: linux 1.3.95, Pentium 100, UART16550A working: sendfax, mgetty-0.98 remarks: no FAX polling mode (neither client nor server); newer V.34 modem not tested (my modem has only V.fast-class); no FAX Class 2.0 (only Class 2). policy.h: #define FAX_SEND_INGORE_CARRIER /* required!! */ mgetty.config: speed 38400 switchbd 38400 init-chat "" \d\d\d+++\d\d\dAT OK ATH0 OK AT&FB2E0L1M0S0=0 OK sendfax.config: modem-init AT&FB2E0L1M0S0=0 switchbd 38400 speed 38400 contributor: thielen@lpr.e-technik.tu-muenchen.de ----------------------------------------------------------------------- Modem brand/model: "AT&T" (1428VQE) (no-brand manufacturer using AT&T chipset). at+fmfr? AT&T at+fmdl? HSM288xCF at+frev? V4.00 ati3 DDS-03 9/27/95 ati4 007040C0040000 tested on: linux 1.2.1 working: mgetty (data incoming, login and incoming fax) remarks: This is the setup for this modem as of my mgetty.config: port ttyS1 speed 38400 init-chat "" \d\d\d+++\d\d\d\dAT&F OK ATZ OK ATE0L0 OK modem-type cls2 switchbd 19200 MAKE SURE ATE0 is selected. This modem defaults to echo on (ATE1) and that confuses mgetty causing fax reception to fail. contributor: rr@mn.village.it (Ruggero Ruberti) #define DATA_FLOW FLOW_HARD #define FAXREC_FLOW FLOW_HARD | FLOW_SOFT ----------------------------------------------------------------------- Modem: MVP288XV Cardinal 28800 ext. voice/fax/modem OS: Linux 1.3.97 on pentium-120 Init: AT&F /etc/mgetty.config: switchbd 19200 # No faxes else! modem-type cls2 # works without this also All other settings are untouched. contributor: georgiev@generation.net ----------------------------------------------------------------------- Modem brand/model: ViVa 14.4/Fax from Computer Peripherals AT+FMFR? ROCKWELL AT+FMDL? RC32ACL AT+FREV? V1.000 ATI0 14400 ATI1 007 ATI4 AT-1414PKM V1.00 STANDARD VERSION 4.7.1993 AT&V ACTIVE PROFILE: B0 E1 L1 M1 N1 Q0 T V1 W1 X4 Y0 &C1 &D2 &G0 &J0 &K3 &Q5 &R1 &S0 &T4 &X0 &Y0 tested on: Solaris 2.5 SunOS 4.1.3 and 4.1.4 working: sendfax, mgetty remarks: contributor: rrb@cqs.ch /* changed values in policy.h: */ #define MODEM_INIT_STRING "ATZ" #define FAX_MODEM_HANDSHAKE "AT&K3" - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Modem brand/model: "1&1 Speedster 14400" AT+FMFR? CIS AT+FMDL? CEUSBEXX V1.03 31/01/96 AT+FREV? VERSION 1.03 01-05-01-01 ATI0 144 ATI1 048 ATI3 CEUSBEXX V1.03 31/01/96 ATI4 UMC V.32bis/FAX/VOICE MODEM ATI6 AT+FDCC=? (0,1),(0-5),(0-3),(0-2),(0),(0),(0),(0-7) tested on: Sun Solaris 2.5 with Sun C-Compiler working: sendfax remarks: mgetty not tested (no need for it at the moment) contributor: Alexander.Zimmermann@FMI.Uni-Passau.De #define DEFAULT_PORTSPEED 19200 #define MODEM_INIT_STRING "ATS0=0Q0&D3&C1&K3" #define FAX_SEND_BAUD 19200 #define FAX_MODEM_HANDSHAKE "AT&K3" #define FAX_MODEM_TTYS "/dev/term/a" #define FAXSEND_NO_XON /* does not work without this !! */ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - Date: Thu, 12 Sep 1996 15:50:33 +0200 (MET DST) Thank you Gerd for your marvellous programm. And many thanks to all others involved in this endeavour. It's all set up and working fine on my machiene. As you adviced, I got me another modem. The Creatix 144VFi is sold now for 75DM. I think they are clearing it out. So if anybody likes it, get it now. By the way, the included software for DOS/win is nice but it doesn't work. I have in my Linux Box this modem running with mgetty99-Aug26 and a Creatix ISDN Card (Baugleich mit Teles 16.0) with vboxgetty. Since the voice functions work so well with ISDN, I didn't even try to get them working with the modem. It is used mainly for faxing and sometimes to call a BBS with no ISDN port. Everything else is done with the ISDN card. And here the configuration data for the modem.db: Modem brand/model: Creatix 144VFi PhoneMaster / fax modem ############################################################## AT+FMFR? CIS AT+FMDL? CCUSBIXX V1.10 10/10/95 AT+FREV? VERSION 1.10 01-05-01-01 ATI0 144 ATI1 134 ATI3 CCUSBIXX V1.10 10/10/95 ATI4 UMC V.32bis/FAX/VOICE MODEM AT+FDCC=? (0,1),(0-5),(0-3),(0-2),(0),(0),(0),(0-7) tested on: kernel 2.0.15 working: sendfax, mgetty contributor: weizenkeim@t-online.de #define DEFAULT_PORTSPEED 38400 #define MODEM_INIT_STRING "ATS0=0Q0&D3&K3" #define MODEM_CMD_SUFFIX "\r" #define DEFAULT_MODEMTYPE "cls2" #define DO_CHAT_SEND_DELAY 50 #define FAX_COMMAND_DELAY 50 #define DATA_FLOW FLOW_HARD #define FAXREC_FLOW FLOW_HARD | FLOW_SOFT #define FAXSEND_FLOW FLOW_HARD | FLOW_SOFT #define FAX_RECV_SWITCHBD 19200 #define FAX_SEND_BAUD 19200 #define FAX_SEND_SWITCHBD 19200 #define FAX_MODEM_HANDSHAKE "AT&K3" ----------------------------------------------------------------------- Modem brand/model: "Bocamodem 14.4Kbps V.32bis" at+fmfr? ROCKWELL at+fmdl? RC32ACL at+frev? V1.300-AS29 ati3 V1.300-AS29 ati4 14,400 bps tested on: Linux 2.0.18 - Rocketport 8 port board, comtrol.1.11 driver module working: sendfax, mgetty contributor: don@marinelab.sarasota.fl.us ---- #ident "@(#)policy.h 3.6 96/07/09 Copyright (c) Gert Doering" #define DEFAULT_MODEMTYPE "cls2" #define DATA_FLOW FLOW_HARD #define FAXSEND_FLOW FLOW_SOFT #define FAX_SEND_BAUD 19200 ---- # sendfax configuration file fax-devices ttyR0 port ttyR0 modem-handshake AT&K4 ---- # mgetty configuration file port ttyR0 init-chat "" \d\d\d+++\d\d\dAT&F0\d\dS0=0M0E1X4Q0V1&C1&D2&K OK speed 19200 data-only n ----------------------------------------------------------------------- Modem model: TKR TriStar (OEM Version of ELSA 28.8 TQV) at+fmfr? "" at+fmdl? "TKR TriStar" at+frev? "Ver. 1.16 vom 26.04.96" ati 282 ati1 073 ati2 OK ati3 Ver. 1.16 vom 26.04.96 Initstring: ATL1V1&D3 tested on: Linux Kernel 2.0.18 working: mgetty, vgetty, Fax, Voice, Data remarks: No changes in policy.h. The Company TKR don't know about this Modem, and Elsa ask for at+fmdl? and answer "call TKR" Only for Voice-mode changes in voice.conf: port_speed 38400 port_timeout 15 contributor: Karlo Gross kg@orion.ddorf.rhein-ruhr.de date: Mon Dec 16 19:52:34 1996 ----------------------------------------------------------------------- Modem brand/model: Creatix (?) 1&1 Speedster 14400U (grün) AT+FMFR? CIS AT+FMDL? CEUSBEXX V1.03 31/01/96 AT+FREV? VERSION 1.03 01-05-01-01 ATI3 CEUSBEXX V1.03 31/01/96 ATI4 UMC V.32bis/FAX/VOICE MODEM AT+FDCC=? (0,1),(0-5),(0-3),(0-2),(0),(0),(0),(0-7) system: Linux 2.0.18, i486 contributor: martin.stechert@t-online.de Date: Sun, 12 Jan 1997 19:59:45 +0100 (CET) #define DEFAULT_PORTSPEED 38400 #define MODEM_INIT_STRING "ATV1Q0" #define DATA_FLOW FLOW_HARD #define FAXREC_FLOW FLOW_HARD | FLOW_SOFT #define FAX_MODEM_HANDSHAKE "AT&K3" #define FAX_DIAL_PREFIX "ATD" #define FAXSEND_NO_XON /* !!!!! */ ----------------------------------------------------------------------- Modem brand/model: "IDC-1914BXL 19200 bps FAX-MODEM" at+fmfr? IDC at+fmdl? IDC at+frev? FAX Version 4.02 ati3 IDC-1914BXL V.32terbo/V.42bis firmware by Mike Telis, Ver. 2.21 ati6 Copyright INPRO, 1994-96. Tech support hot line (095) 265-0238. tested on: FreeBSD 2.1.0 working: mgetty, sendfax (both 0.99.9) remarks: This modem is very popular with fidonet sysops in Russia. It is certified by the Russian Ministry of Communications and has a lot of features to tweak it so that it works on poor lines where other modems inevitably fail. remarks (2): Something very weird is happening when receiving faxes -- sometimes it just "stops"...!!?? contributor: vas@vas.tomsk.su date: Mon, 27 Jan 97 19:46:18 +0700 #define DEFAULT_PORTSPEED 38400 #define MODEM_INIT_STRING "ATZ" #define MODEM_CMD_SUFFIX "\r" #define DEFAULT_MODEMTYPE "auto" #define DO_CHAT_SEND_DELAY 50 #define FAX_COMMAND_DELAY 50 #define DATA_FLOW FLOW_HARD #define FAXREC_FLOW FLOW_SOFT #define FAXSEND_FLOW FLOW_SOFT #define FAX_SEND_BAUD 19200 #define FAX_MODEM_HANDSHAKE "AT&K3" ----------------------------------------------------------------------- Modem brand/model: ELSA Microlink 28.8 TQV AT+FMFR? "ELSA, Aachen (Germany)" AT+FMDL? "MicroLink 28.8TQV" AT+FREV? "Ver. 1.10 vom 19.09.95" ATI3 Ver. 1.10 vom 19.09.95 AT+FDCC=? (0,1),(0-5),(0-2),(0-2),(0),(0),(0),(0-7) tested on: OS: Linux, Kernel: 2.0.25, Distribution: Suse 4.4 (mgetty-1.1.1-Jan28) Computer: Pentium 166 working: sendfax, mgetty contributor: ai@easy.in-chemnitz.de remarks: same executable runs with slighly modified init-chat with ELSA Microlink ISDN/TLV.34 #define DEFAULT_PORTSPEED 38400 #define MODEM_INIT_STRING "\\dATS0=0Q0&D2&K3N1%E1&Q5" #define DATA_FLOW FLOW_HARD #define FAXREC_FLOW FLOW_HARD | FLOW_SOFT #define FAXSEND_FLOW FLOW_HARD | FLOW_SOFT #define FAX_SEND_BAUD 19200 #define FAX_MODEM_HANDSHAKE "AT\\Q3&S0" ----------------------------------------------------------------------- Modem brand/model: "Designer Modem (NoName)" at+fmfr? ACEEX at+fmdl? 9624,2,E,290E at+frev? Sep-24-1991 ati3 ati6 V2.7 MAY-27-94 DM1414/2A/RC144DP-21/PCB:490-09636-xx BZT POSTZULASSUNG-FIRMWARE VERSION:V.105 tested on: Linux 1.2.x and 2.0.x working: mgetty, sendfax remarks: Works fine. contributor: ht@rosenthal.ohz.north.de (Hermann Treu) date: 21 Mar 97 16:49:30 +0100 #define FAX_COMMAND_DELAY 50 #define FAXREC_FLOW FLOW_HARD | FLOW_SOFT #define FAXSEND_FLOW FLOW_HARD | FLOW_SOFT #define DEFAULT_PORTSPEED 38400 #define FAX_SEND_BAUD 19200 #define FAX_RECV_SHWITCHBD 19200 #define FAX_MODEM_HANDSHAKE "AT&K3" #define MODEM_INIT_STRING "AT%T1S0=0E0Q0V1&C1&D3" ----------------------------------------------------------------------- Date: Thu, 8 May 1997 08:25:39 +0000 () From: Felipe Rivera Marquez <felipe@informador.com.mx> To: Gert Doering <gert@greenie.muc.de> Subject: Motorola ModemSURFR entry for modems.db Modem brand/model: "Motorola ModemSURFR 28.8 External"" at+fmfr? AT&T at+fmdl? HSM288xCF at+frev? CL2 V4.00 ati3 Motorola ModemSURFR 28.8 ati4 007040C0040000 at&v STORED PROFILE 0: B1 E0 L1 M1 Q0 V1 W0 X4 &B1 &C1 &D2 &G0 &L0 &P0 &Q0 &R0 &S0 &X0 %A013 %C1 %G1 \A3 \C0 \G0 \J0 \K5 \N3 \Q3 \T000 \V0 \X0 -J1 "H3 "O032 S00:000 S02:043 S03:013 S04:010 S05:008 S06:002 S07:045 S08:002 S09:006 S10:014 S11:095 S12:050 S18:000 S25:005 S26:001 S37:000 S72:000 tested on: Linux 2.0.18 (Distribution RedHat 4.0) working: mgetty remarks: &D2 sould be &D3 in the STORED PROFILE 0 (active DTR hang and reset modem) but it was easier to set &D3 in the init-string on mgetty.config Set toggle-dtr-waittime in mgetty.config to 2000, it seems that 50 (the default) is not enough for this modem. All the modems are working with a Comtrol Rocketport ISA 32 ports. Maybe you should decrease DO_CHAT_SEND_DELAY and toggle-dtr-waittime. I just set them high because i was getting mad and when the modems stopped going away, i just said to me: No more changes, don't touch the settings anymore :). I use the modems for data only. Some of the commands in the init-strings are unnecesary, but, well.... the modems are working without trouble. contributor: felipe@informador.com.mx #define MODEM_CHECK_TIME -1 #define DEFAULT_MODEMTYPE "data" #define DO_CHAT_SEND_DELAY 1000 -------------- mgetty.config # global settings init-chat "" ATZ OK AT OK AT&D3ELS2=255S0=0 OK force-init-chat "" \\d\\d\\d\\d\\d\\d+++\\d\\d\\dATH OK ATZ OK AT OK AT&FELS2=255 OK ATS0=0&D3 toggle-dtr-waittime 2000 ----------------------------------------------------------------------- Date: Sun, 1 Jun 1997 20:31:35 +0200 (MET DST) From: Peter Gerland <peter@peges.central.de> To: Gert Doering <gert@greenie.muc.de> Subject: Re: CYBERMOD und mgetty Modem brand/model: "Dr. Neuhaus CYBERMOD 28.8 V.34" at+fmfr? Dr. Neuhaus at+fmdl? LC 28.8 TI DNT 1175 at+frev? V.0.00.0680 ati0 28800 ati1 255 ati8 AT&T V.34 Datapump Version 2.5 ati+FDCC? 28800 1,5,0,2,0,0,00 tested on: Linux 2.0.30 working: mgetty, sendfax mgetty-version 1.1.6 remarks: Works after comment mg_m_init.c the line with "/* if ( mdm_command( "AT+FCLASS=0",fd) == FAIL) */" thanks to Gert Doering contributor: peter@peges.central.de date: 21 May 97 22:30 #define FAX_COMMAND_DELAY 50 #define FAXREC_FLOW FLOW_HARD | FLOW_SOFT #define FAXSEND_FLOW FLOW_HARD | FLOW_SOFT #define DEFAULT_PORTSPEED 38400 #define FAX_MODEM_HANDSHAKE #define MODEM_INIT_STRING "AT&FS0=0M0L3\\\\q3\\\\J1" ----------------------------------------------------------------------- Modem brand/model: "Dr. Neuhaus FURY 14.4 TI" at+fmfr? Dr. Neuhaus Mikroelektronik GmbH at+fmdl? FURY (R) 14.4 Ti at+frev? Version 3.000 ati0 962 ati1 000 ati8 ... ati9 FURY (R) 14.4 Ti Version 3.000 Data Pump Version 2.200 MNP/V.42 Version 7.000 ati+FDCC? 962 0,3,0,0,0,0,0,5 tested on: Linux 2.0.30 working: mgetty, sendfax mgetty-version 1.1.9 contributor: bartels@bartels.com date: 20 Oct 97 #define FAX_COMMAND_DELAY 50 (default) #define FAXREC_FLOW FLOW_HARD | FLOW_SOFT (default) #define FAXSEND_FLOW FLOW_HARD | FLOW_SOFT (default) #define DEFAULT_PORTSPEED 38400 (default) #define FAX_MODEM_HANDSHAKE (default) -------------- mgetty.config # port settings modem-type cls2 switchbd 19200 -------------- sendfax.config # port settings modem-type cls2 ignore-carrier y switchbd 19200 ----------------------------------------------------------------------- Contributor: Nick Holloway <Nick.Holloway@alfie.demon.co.uk> Modem: ACCURA 33600, Model 5349GB, Version 6.20 at+fmfr? Copyright 1995, 1996 Hayes Microcomputer Products, Inc. at+fmdl? ACCURA 33600 at+frev? Version 6.20 tested on: Linux 1.2.30, mgetty 1.0.0 working: mgetty, sendfax remarks: The setting of S101 is just for distinctive ring. mgetty.config: speed 115200 switchbd 0 init-chat "" \d\d\d+++\d\d\dATZ OK ATS101=61 OK answer-chat "" AT+FCLASS=2;A CONNECT \c \r ----------------------------------------------------------------------- Subject: Re: patch for mgetty Date: Fri, 01 May 1998 10:11:17 +0200 From: Quercia Michel <quercia@cal.enst.fr> Modem brand/model: "Kortex Adaptix 56000" at+fmfr? Venus K56FLEX kfav141 Serial s091097V at+fmdl? Venus K56FLEX kfav141 Serial s091097V at+frev? s091097V ati0 KORTEX ADAPTIX 56K FRANCE V1.00 110 780 00 ati1 0000 ati2 ati3 Venus K56FLEX kfav141 Serial s091097V ati4 KORTEX ADAPTIX 56K FRANCE V1.00 110 780 00 ati5 s091097V,0,05 ati6 at+fdcc=? (0,1),(0-5),(0),(0-2),(0),(0),(0),(0-7) at+vcid=? (0-2) tested on: linux 2.0.29 working: mgetty (fax not tested) remarks: poor doc, you'll have to phone Kortex (several times) to get info about AT sequences. To get caller-Id report, send "at+vcid=1" contributor: quercia@cal.enst.fr ----------------------------------------------------------------------- Date: Wed, 20 May 1998 21:18:27 +0200 From: Karel Vanthuyne <Karel.Vanthuyne@village.uunet.be> Subject: Re: latest release of mgetty (1.1.14) solved the problems with my E-tech modem! Modem brand/model: E-Tech Golden Bullet E336RVP ATJ E336RVP, 00, Ver 8.00, A75F, RCV336ACF/SP ATI0 33600 ATI3 V2.050-V34_ACF_DS1 ATI6 RCV336DPFSP Rev 44BC AT+FCLASS=? 0,1,1.0,80 tested on: Linux 2.0.30 (RedHat 4.2)/UART 16550A working: vgetty contributor: Karel.Vanthuyne@village.uunet.be changes in voice.conf: port_speed 115200 policy.h: #define DEFAULT_PORTSPEED 115200 #define MODEM_INIT_STRING "ATV1E1&D3&C1X4&K3Q0W2N1L0S11=100" #define MODEM_CMD_SUFFIX "\r" #define DEFAULT_MODEMTYPE "auto" #define DO_CHAT_SEND_DELAY 50 #define DATA_FLOW FLOW_HARD Remark: Note that this modem only supports fax class 1 and 1.0 Setting the modem-type to "auto" is harmless: vgetty doesn't detect fax class 2/2.0 capability and just disables faxing. Which is fine if you're only interested in using this modem for incoming voice calls and data calls. The modem doesn't seem to automatically distinguish between voice and data, so I wrote a script to take care of that (caller has to press "0" to get a data answering tone next time he calls). However, it seems that work is in progress for fax class 1 support 8-) I use efax for sending faxes right now. ----------------------------------------------------------------------- Date: Wed, 22 Jul 1998 19:16:04 -0300 From: Claudemir Todo Bom <allgood@conection.com.br> To: Gert Doering <gert@greenie.muc.de>, mgetty@muc.de Subject: Re: Problems on sending to a Toshiba fax machine Modem brand/modem: "Yanco NetSpeed ESV33.6" at+fmfr? CIS at+fmdl? RM-3314E,VERSION 1.10.1a,04-05-02 at+frev? VERSION 1.10.1a,04-05-02 ati3 same as at+fmdl? tested on: Linux 2.0.33 working: sendfax, faxspool, faxrunq (mgetty not tested) remarks: Great work with fax transmission, not tested for incoming faxes and mgetty. Transmits faxes from Brazil to various european countries. Probably available only on Brazilian stores. #define DEFAULT_MODEMTYPE "cls2" /* or auto */ #define FAX_MODEM_HANDSHAKE "AT&K3" /* Rockwell based */ #define FAX_SEND_IGNORE_CARRIER /* only tested with this */ #define FAXSEND_NO_XON /* needed */ ----------------------------------------------------------------------- Date: Tue, 25 Aug 1998 21:22:57 +0300 (EEST) From: Olli Arnberg <oar@leka.hut.fi> To: gert@greenie.muc.de Subject: Thanks for 'modem-quirks' in mgetty-1.1.14 & XLink settings Modem brand/model: XLink V.34 + V.FC (black enclosure) at+fmfr? CIS OK at+fmdl? MC-2814E VERSION 0.20.6 05-04-03 OK VERSION 0.20.6 05-04-03 OK ati0 288 OK ati3 MC-2814E VERSION 0.20.6 05-04-03 OK ati4 OK at+fdcc=? (0,1),(0-5),(0-3),(0-2),(0),(0),(0),(0-7) OK at&v ACTIVE PROFILE: B0 E1 L2 M1 N1 Q0 T V1 X4 Y0 &C1 &D2 &G0 &L0 &M0 &P0 &R0 &S0 &T4 &X0 &Y0 %A000 %B28800 %C1 %D0 %E2 %N0 \A3 \C0 \G0 \J0 \K5 \M0 \N3 \Q3 \T000 \V2 \X0 S00:000 S02:043 S03:013 S04:010 S05:008 S06:002 S07:045 S08:002 S09:006 S10:014 S11:095 S12:050 S13:000 S18:000 S25:005 S26:001 S29:000 S30:000 S91:012 tested on: Debian/GNU/Linux 2.0.0 (hamm), kernel 2.0.27 mgetty version: 1.1.14 (Debian 1.1.14-2) working: mgetty, sendfax remarks: sendfax and mgetty (only fax tested) work contributor: oar@cc.hut.fi (Olli Arnberg) /etc/mgetty/mgetty.config: # ----- port specific section ----- # Our XLink Rockwell modem, needs "switchbd 19200" to receive faxes # properly (otherwise it will fail with "timeout"). port ttyXX speed 38400 switchbd 19200 /etc/mgetty/sendfax.config: # ----- port specific section ----- # Our XLink: port ttyXX modem-type cls2 ignore-carrier ## NO_XON before sending next fax page although Class 2 modem: modem-quirks 8 ----------------------------------------------------------------------- Date: Sat, 3 Oct 1998 09:28:44 +0200 From: Ulf Steinberg <ulmo@rz.uni-karlsruhe.de> Modem brand/model: USRobotics Sportster Message Plus AT+FMFR? ??? AT+FMDL? ??? AT+FREV? ??? ATI0 5601 ATI1 5D48 ATI4 U.S. Robotics 56K Message Settings... B0 E1 F1 L1 M1 Q0 V1 X4 Y0 BAUD=115200 PARITY=N WORDLEN=8 DIAL=PULSE ON HOOK [...] ATI7 Configuration Profile... Product type Germany External Product ID: 02206800 Options V32bis,V.34+,x2,V.90 Fax Options Class 1/Class 2.0 Voice Options Speaker Phone, TAD Clock Freq 92.0Mhz EPROM 256k RAM 32k FLASH date 2/24/98 FLASH rev 12.1.14 DSP date 2/24/98 DSP rev 12.1.14 tested on: Linux (SuSE 5.2) Kernel 2.0.33 working: sendfax, mgetty, vgetty remarks: Fax polling isn't working (due to the modem.) for vgetty, the AT+MCS=0 command is very important to "revive" the modem after a voice session. contributor: ulmo@rz.uni-karlsruhe.de thanksto: Michael Witschke Defines in policy.h #define MODEM_INIT_STRING "AT+MCS=0S0=0Q0&D3&C1" //To turn of the local mode #define FAX_USRobotics //respectively modem-quirks 0x20 (Error +FHS:25...) ----------------------------------------------------------------------- From: "Razvan Sandu" <rsandu@go.ro> Subject: mgetty works fine with DAVICOM modems Date: Sun, 15 Nov 1998 02:08:20 +0200 [..] mgetty and sendfax works fine on my Pentium MMX 233 system, equipped with an internal DAVICOM PnP voice/fax/data modem (an ISA board). So, I hereby send you my configuration parameters, in order to be included in modems database, if useful. Modem information ATI V3.00 ATI2 TEST OK ATI3 DAVICOM DATA/FAX MODEM, DATE 97/09/22 ATI4 DAVICOM V.34+/FAX/VOICE/SPEAKERPHONE MODEM/Ver 1.09 ATI5 OK ATI6 OK ATI7 OK AT+FCLASS=? 0,2,8 [..] /etc/mgetty+sendfax/mgetty.config debug 9 modem-type cls2 switchbd 19200 speed 115200 init-chat "" ATZ OK ATS0=3D0Q0E1V1&d2&K4 OK /etc/mgetty+sendfax/sendfax.config verbose y debug 9 speed 38400 switchbd 19200 fax-devices ttyS3 modem-type cls2 modem-init ATZ modem handshake AT&K4 dial-prefix ATDP ----------------------------------------------------------------------- Date: Wed, 10 Mar 1999 15:06:43 +0800 From: "Peter T. Caffin" <pc@it.net.au> Message-Id: <199903100706.PAA27593@belgarion.it.net.au> To: gert@greenie.muc.de (Gert Doering) Modem brand/model: Dynalink 1428VQE at+fmfr? ROCKWELL at+fmdl? AC/V34 at+frev? CRS-02 AST 950921 ati3 CRS-02 AST 950921 ati6 RC288DPi Rev 0 tested on: Linux 2.2.2 working: mgetty, sendfax mgetty.config: speed 38400 modem-type cls2 switchbd 19200 (INSTALLED FROM A .RPM OF MGETTY-SENDFAX 1.1.14) remarks: Looking at the Dynalink 9624AP, you'd think that using this modem would be a doomed exercise. Actually, it was a pretty easy modem to install and use. It's an older 28.8k model, so you're more likely to encounter it second-hand. contributor: Peter Caffin <pc@it.net.au> date: Wed Mar 10 14:40:35 WST 1999 -----------------------------------------------------------------------